● Standard
This product implements: IEC 60092-376 standard.
● For laying indoorsin tunnels or cabletrench, unable tobear external mech-anical forces.
Single-core cable inmagneticduct is notpermissible.
● Conductor
Electrolytic copper, class 5 (flexible), Aluminum conductor according to IEC 60228.
● Insulation
Cross-linked polyethylene, type HF XLPE 90ºC, Conforms to IEC 60092-353.
● The standard identification of insulated conductors according to HD 308 is the following
1 x Natural
3 x Brown + Black + Grey
4 x Brown + Black + Grey + Blue
Other colors available on request.
Insulation core with white insulation printed with black numerical markings
Sheath prints manufacturer's name, model, voltage, specification, length marking, etc.
● Outer sheath
LSHF polyolefin outer sheath type SHF1 according to IEC 60092-360. Black color.
Type | Cable name | Scope of use | |
YJV22 | Copper conductor XLPE insulated steel tape armoured PVC sheathed Power cable | For laying in doors 、 in tunnels or cable trench,or direct in ground,able to bear external mechanical forces,but unable to bear large pulling force |
|
YJLV22 | Aluminium conductor XLPE insulated steel tape armoured PVO sheathed Power cable | ||
YJV23 | Copper conductor XLPE insulated steel tape armoured PE sheathed Power cable | ||
YJLV23 | Aluminum conductor XLPE insulated steel tape armoured PE sheathed Power cable | ||
YJV32 | Copper conductor XLPE insulated steel wire armoured PVC sheathed Power cable | For laying in doors 、 in tunnels,cable trench ,well or direct in ground ,able to bear external mechanical forces and Determinate pulling force. |
|
YJLV32 | Aluminum conductor XLPE insulated steel wire armoured PVC sheathed Power cable | ||
YJV33 | Copper conductor XLPE insulated steel wire armoured PE sheathed Power cable | ||
YJLV33 | Aluminium conductor XLPE insulated steel wire armoured PF sheathed Power cable |
Product description
Current carrying rating factors for different ambient air temperature
Current carrying rating factors for different soil temperature
Product display
Power cable certificate display
XLPE insulated power cable for rated voltage 3.6/6kV
Nominal Cross Sectional area of conductor mm² |
Max.D.C resistance of conductor at 20℃ (Ω/km) |
|||
Copper |
Aluminum |
|||
1 |
18.1 |
- |
||
1.5 |
12.1 |
- |
||
2.5 |
7.41 |
- |
||
4 |
4.61 |
- |
||
6 |
3.08 |
- |
||
10 |
1.83 |
3.08 |
||
16 |
1.15 |
1.91 |
||
25 |
0.727 |
1.20 |
||
35 |
0.524 |
0.868 |
||
50 |
0.387 |
0.641 |
||
70 |
0.268 |
0.443 |
||
95 |
0.193 |
0.320 |
||
120 |
0.153 |
0.253 |
||
150 |
0.124 |
0.206 |
||
185 |
0.0991 |
0.164 |
||
240 |
0.0754 |
0.125 |
||
300 |
0.0601 |
0.100 |
||
400 |
0.0470 |
0.0778 |
||
500 |
0.0366 |
0.0605 |
||
630 |
0.0283 |
0.0469 |
||
800 |
0.0221 |
0.0367 |
||
Power frequency |
Test voltage 3.5kV/5min |