loading

Focusing On The Research, Development, Production And Sales Of Wires And Cables.

about nuclear cable
Nuclear Power Plant cable

Nuclear power plant cable refers to the raw materials used in the insulation and sheath of nuclear power plant cables, including plastic, rubber and other varieties. The type of cable is determined by the type of cable.

no data
Types

Nuclear power plant cables have two classification methods: one by function, including measurement cables, communication cables, instrumentation cables, fire cables (silicone-insulated cables), etc.; the other is by safety level, nuclear power plant cables with the safety level belongs to the IE level, at the same time, it should have a service life of more than 4O years, IE level nuclear power plant cables and is divided into K1, K2 and K3, the three safety levels. The development process of nuclear power plant cable products is essentially the renewal of the material, the type of cable and its choice of raw materials.

Medium Voltage Cable Detail Show
Medium Voltage Cable Composite View
Advanced production equipment and technology, strict quality control system, high production efficiency, excellent product performance, green environmental protection.
no data
High purity electrolytic copper
Selecting 1# electrolytic copper with a copper content of more than 99.95%
PVC/XLPE 
Good electrical insulation properties, can effectively prevent current leakage
Steel tape/Steel wire Armored
Resistant to a wide range of external stresses and erosion
Copper Shield
Good conductivity and shielding properties
no data
Why choose us for wire and cable?

NO.1, Jiangnan Cable has advanced production technology and equipment. From the manufacturing of conductors to the processing of insulation, shielding and sheathing, every step is precise and strict to ensure the high quality of medium voltage cables.


NO.2, the quality control is extremely strict. The company has established a perfect quality inspection system, from the selection of raw materials to the finished products leaving the factory, checking at every level. Each medium-voltage cable has to go through a number of strict tests to ensure that the products meet or even exceed the national standards.


NO.3, Jiangnan Cable has invested heavily in research and development. According to the market demand and customers' special requirements, we can develop medium voltage cables with different characteristics, such as better environmental resistance and better current carrying capacity. Moreover, the rich product line can meet the different needs of various complex projects and provide customers with one-stop cable solutions.





Our Cases

what we finished

We have a high degree of manufacturing depth, short lead time and flexibility in every sense. Whatever your need is, we are happy to help. If you have a new idea that you want to bring to reality or an existing design that needs improvement, we look forward to an opportunity to discuss it with you.
no data


                                    Jiangnan Cable Customized Service
Customized  Cable Specifications Insulation Material Shield Construction  Sheath Material Armor Structure Special Performance Length 
Conductor Cross Section Number of cores Material Type  Insulation Thickness  Shielding type Number of Shielding Layers Material Selection Color Identification  Armor type Armor Layers Fire resistance Waterproof performance  Flame retardant performance  Cold resistance  Sample customization request meters

 

Interested?
Request A Call From A Specialist
Customized solutions for your wire and cable projects. Get complete solutions for customized wire and cable projects. Get technical support for wire and cable structure design, installation and correction.

Characteristics

Performance low smoke

The insulation and sheath materials of cables for nuclear power plants must be low-smoke, non-toxic, non-corrosive halogen-free flame-retardant cables, such as thermoplastic flame-retardant halogen-free or cross-linking flame-retardant halogen-free materials, in order to meet the special nuclear safety requirements. Halogen-free cables in the event of a fire, the amount of smoke released by combustion is very low, without toxicity and corrosiveness, and its flame retardant components can effectively play the role of flame retardant, will not make the cable become a channel for the spread of flame. The main technical characteristics of halogen-free flame retardant cables are: (1) the total cumulative amount of smoke from nuclear power plant cables Dm <150; (2) non-toxic and corrosive, i.e., the cable combustion does not precipitate HCI and CO; (3) has a flame retardant, polymer flame retardant is usually evaluated by the oxygen index (0I) method, the general OI 28.



Environmental resistance

Nuclear power plant cable materials must have environmental resistance, namely heat resistance, irradiation resistance and LOCA resistance.

(1) heat resistance due to nuclear power plant cables often work in high temperature environments, high temperature cables. Therefore they need to have a long-term heat-resistant use of performance, to choose the heat resistance to meet the requirements of the polymer, and can make the cable has a service life of more than 40 years.

(2) irradiation resistance (moderate environment, harsh environment) nuclear power plant cables are subjected to a large number of rays will make the insulation and sheath materials become brittle, poor mechanical properties. Therefore, as a nuclear power plant cable insulation and sheath materials, must have excellent irradiation resistance. Different polymers have different irradiation resistance properties. People usually add anti-irradiation agent in the polymer to improve its irradiation resistance.

(3) LOCA resistance in nuclear power plants, usually the loss of coolant accident (Lossofcoolingaccident, LOCA) and high-energy tube rupture accident (Highenergylinebreak, HELB) collectively referred to as LOCA. in the event of LOCA/HELB, the cable will be subjected to high-temperature and high-pressure steam impact and corrosive chemicals Role, and to be subjected to a higher dose of radiation than under normal operating conditions. Therefore, nuclear power plant cables should be LOCA resistant.r power plant cable materials must have environmental resistance, namely heat resistance, irradiation resistance and LOCA resistance.

Performance Requirements

 Nuclear power plants have very strict requirements for the use of cable conditions. Cables should be able to be buried directly through cable ducts and underground pipes, or installed overhead through cable trays, cable ducts and wiring ducts, etc., and at the same time, they should be able to work in dry and warm environments:

 

  (1) Service life. The design life of heavy water reactor nuclear power plants is generally 40 years, and the service life of cables is at least 40 years.

 

  (2) Thermal stability. In the case of being at the maximum ambient temperature and its own heat generation, the cable shall be able to maintain the insulation performance required by the operating conditions. The minimum continuous insulation operating temperature for power and control cables is 90°C.

 

  (3) Moisture resistance. In the event of fire sprinkler splashing under accident conditions, the cable shall be able to operate normally in a 100% relative humidity environment.

 

  (4) Fire resistance. In order to reduce the potential impact and damage caused by the cable catching fire, the cable shall be flame retardant.

 

  (5) Chemical stability. Cables installed in chemical environments (e.g., oil, ozone, acids and alkalis, and other corrosive agents) shall maintain the required insulation properties.

 

  (6) Radiation resistance. During the operation of the power station, the cable should be able to receive a continuous radiation dose of 10 rad / h, the cumulative dose over 40 years is about 0.4 × 107 rad, in the accident state radiation dose can be up to 5 × 107 rad. after withstanding the total cumulative radiation dose, the cable should still maintain the electrical properties unchanged.

Small Text
no data
Our related products
no data
Our Related Certifications 
no data
We are a National Key High and New Tech Enterprise specialized in production, sales and research on wires and cables.
Contact person: Wilco Zhong
Contact number: 86-13372003527
WhatsApp: 86-13372003527
Contact person: Kelly Lu
Contact number: 86-17368475715
WhatsApp: 86-17368475715
Copyright © 2025 Jiangnan Cable | Sitemap
Customer service
detect