Concentrandosi sulla ricerca, sviluppo, produzione e vendita di fili e cavi.

about nuclear cable
Nuclear Power Plant cable

Nuclear power plant cable refers to the raw materials used in the insulation and sheath of nuclear power plant cables, including plastic, rubber and other varieties. The type of cable is determined by the type of cable.

nessun dato
Types

Nuclear power plant cables have two classification methods: one by function, including measurement cables, communication cables, instrumentation cables, fire cables (silicone-insulated cables), etc.; the other is by safety level, nuclear power plant cables with the safety level belongs to the IE level, at the same time, it should have a service life of more than 4O years, IE level nuclear power plant cables and is divided into K1, K2 and K3, the three safety levels. The development process of nuclear power plant cable products is essentially the renewal of the material, the type of cable and its choice of raw materials.

Spettacolo dettagliato del cavo di media tensione
Vista composita del cavo di media tensione
Attrezzature e tecnologie di produzione avanzate, rigoroso sistema di controllo qualità, elevata efficienza produttiva, eccellenti prestazioni del prodotto, protezione ambientale ecologica
nessun dato
Rame elettrolitico di elevata purezza
Selezione del rame elettrolitico 1# con un contenuto di rame superiore al 99,95%
PVC/XLPE 
Buone proprietà di isolamento elettrico, possono prevenire efficacemente le perdite di corrente
Nastro d'acciaio/filo d'acciaio armato
Resistente ad una vasta gamma di sollecitazioni esterne ed erosione
Scudo di rame
Buone proprietà di conduttività e schermatura
nessun dato
Perché sceglierci per fili e cavi?

NO.1, Jiangnan Cable dispone di tecnologie e attrezzature di produzione avanzate. Dalla produzione dei conduttori alla lavorazione degli isolamenti, delle schermature e delle guaine, ogni passaggio è preciso e rigoroso per garantire l'alta qualità dei cavi di media tensione.


NO.2, il controllo di qualità è estremamente rigoroso. L'azienda ha istituito un perfetto sistema di controllo qualità, dalla selezione delle materie prime ai prodotti finiti che lasciano la fabbrica, controllando ad ogni livello. Ogni cavo di media tensione deve essere sottoposto a una serie di test rigorosi per garantire che i prodotti soddisfino o addirittura superino gli standard nazionali.


NO.3, Jiangnan Cable ha investito molto nella ricerca e nello sviluppo. In base alla domanda del mercato e alle esigenze particolari dei clienti, possiamo sviluppare cavi di media tensione con caratteristiche diverse, come una migliore resistenza ambientale e una migliore capacità di trasporto di corrente. Inoltre, la ricca linea di prodotti può soddisfare le diverse esigenze di vari progetti complessi e fornire ai clienti soluzioni di cavi complete.





I nostri casi

Quello che abbiamo finito

Abbiamo un alto grado di profondità di produzione, tempi di consegna brevi e flessibilità in tutti i sensi. Qualunque sia la tua necessità, siamo felici di aiutarti. Se hai una nuova idea che vuoi portare alla realtà o un design esistente che necessita di miglioramenti, non vediamo l'ora di avere l'opportunità di discuterne con te.
nessun dato


                                    Servizio personalizzato via cavo Jiangnan
Personalizzato  Specifiche del cavo Materiale isolante Costruzione dello scudo  Materiale della guaina Struttura dell'armatura Prestazione speciale Lunghezza 
Sezione trasversale del conduttore Numero di core tipo di materiale  Spessore dell'isolamento  Tipo di schermatura Numero di strati di schermatura Selezione del materiale Identificazione del colore  Tipo di armatura Strati di armatura Resistenza al fuoco Prestazioni impermeabili  Prestazioni ignifughe  Resistenza al freddo  Campione di richiesta personalizzazione contatori

& Radico;

& Radico; & Radico; & Radico; & Radico; & Radico; & Radico; & Radico; & Radico; & Radico; & Radico; & Radico; & Radico; & Radico;

 

Interessato?
Richiedi una chiamata da uno specialista
Soluzioni personalizzate per i vostri progetti di fili e cavi. Ottieni soluzioni complete per progetti di fili e cavi personalizzati. Ottieni supporto tecnico per la progettazione, l'installazione e la correzione di strutture di fili e cavi.

Characteristics

Performance low smoke

The insulation and sheath materials of cables for nuclear power plants must be low-smoke, non-toxic, non-corrosive halogen-free flame-retardant cables, such as thermoplastic flame-retardant halogen-free or cross-linking flame-retardant halogen-free materials, in order to meet the special nuclear safety requirements. Halogen-free cables in the event of a fire, the amount of smoke released by combustion is very low, without toxicity and corrosiveness, and its flame retardant components can effectively play the role of flame retardant, will not make the cable become a channel for the spread of flame. The main technical characteristics of halogen-free flame retardant cables are: (1) the total cumulative amount of smoke from nuclear power plant cables Dm <150; (2) non-toxic and corrosive, i.e., the cable combustion does not precipitate HCI and CO; (3) has a flame retardant, polymer flame retardant is usually evaluated by the oxygen index (0I) method, the general OI 28.



Environmental resistance

Nuclear power plant cable materials must have environmental resistance, namely heat resistance, irradiation resistance and LOCA resistance.

(1) heat resistance due to nuclear power plant cables often work in high temperature environments, high temperature cables. Therefore they need to have a long-term heat-resistant use of performance, to choose the heat resistance to meet the requirements of the polymer, and can make the cable has a service life of more than 40 years.

(2) irradiation resistance (moderate environment, harsh environment) nuclear power plant cables are subjected to a large number of rays will make the insulation and sheath materials become brittle, poor mechanical properties. Therefore, as a nuclear power plant cable insulation and sheath materials, must have excellent irradiation resistance. Different polymers have different irradiation resistance properties. People usually add anti-irradiation agent in the polymer to improve its irradiation resistance.

(3) LOCA resistance in nuclear power plants, usually the loss of coolant accident (Lossofcoolingaccident, LOCA) and high-energy tube rupture accident (Highenergylinebreak, HELB) collectively referred to as LOCA. in the event of LOCA/HELB, the cable will be subjected to high-temperature and high-pressure steam impact and corrosive chemicals Role, and to be subjected to a higher dose of radiation than under normal operating conditions. Therefore, nuclear power plant cables should be LOCA resistant.r power plant cable materials must have environmental resistance, namely heat resistance, irradiation resistance and LOCA resistance.

Performance Requirements

 Nuclear power plants have very strict requirements for the use of cable conditions. Cables should be able to be buried directly through cable ducts and underground pipes, or installed overhead through cable trays, cable ducts and wiring ducts, etc., and at the same time, they should be able to work in dry and warm environments:

 

  (1) Service life. The design life of heavy water reactor nuclear power plants is generally 40 years, and the service life of cables is at least 40 years.

 

  (2) Thermal stability. In the case of being at the maximum ambient temperature and its own heat generation, the cable shall be able to maintain the insulation performance required by the operating conditions. The minimum continuous insulation operating temperature for power and control cables is 90°C.

 

  (3) Moisture resistance. In the event of fire sprinkler splashing under accident conditions, the cable shall be able to operate normally in a 100% relative humidity environment.

 

  (4) Fire resistance. In order to reduce the potential impact and damage caused by the cable catching fire, the cable shall be flame retardant.

 

  (5) Chemical stability. Cables installed in chemical environments (e.g., oil, ozone, acids and alkalis, and other corrosive agents) shall maintain the required insulation properties.

 

  (6) Radiation resistance. During the operation of the power station, the cable should be able to receive a continuous radiation dose of 10 rad / h, the cumulative dose over 40 years is about 0.4 × 107 rad, in the accident state radiation dose can be up to 5 × 107 rad. after withstanding the total cumulative radiation dose, the cable should still maintain the electrical properties unchanged.

Small Text
nessun dato
Our related products
nessun dato
Le nostre certificazioni correlate 
nessun dato
Siamo un'impresa nazionale di alta e nuova tecnologia specializzata nella produzione, vendita e ricerca di fili e cavi.
Persona di contatto: Wilco Zhong
Numero di contatto: 86-13372003527
Muslimate mail: wilco@jncable.com.cn
WhatsApp: 86-13372003527
Persona di contatto : Kelly Lu
Numero di contatto: 86-17368475715
Muslimate mail: kelly@jncable.com.cn
WhatsApp: 86-17368475715
Diritto d'autore© 2024 Cavo Jiangnan  | Mappa del sito
Customer service
detect