loading

Сосредоточение внимания на исследованиях, разработках, производстве и продаже проводов и кабелей.

Туннельный кабель

about ALUMINUM cable
Tunnel Cable

Tunnel Cables, Cable tunnels are corridors or tunnel-like structures used to accommodate large numbers of cables laid on cable supports. In addition to allowing tunnels to better protect cables, cable tunnels can also make it easy to inspect and repair cables.

Brief description

With the development of society, the use of electricity is essential to our lives, and cable tunnels are inextricably linked to electricity. A cable tunnel is a tunnel used for laying cables.

There are many advantages of cable tunnels, the most obvious of which is that it is a one-time investment in the construction of the tunnel and there are a lot of cable supports, after the tunnel is completed, only need to check on time, without having to propose new plans to the relevant departments i

In order to ensure the absolute safety of the tunnels, the tunnels also do a lot of details of the requirements. Cable tunnel inside the design of lighting facilities, when the lighting voltage exceeds 36 volts, it will have an impact on the safety of the tunnel, thus affecting the safety of the cable, so the "Electrical Design Code for Civil Buildings," there are express provisions, lighting facilities in the cable tunnel voltage can not exceed 36 volts, if more than that, it is necessary to take certain safety measures In addition to the lighting requirements, the drainage system in the tunnel there are also certain Requirements. For example, the longitudinal drainage slope of the cable tunnel can not be less than 0.5%, as well as the bottom of the tunnel should be designed to drain, as well as in the tunnel when necessary, mechanical drainage, etc., in the tunnel safety protection, the tunnel to set up a safety hole is very necessary.

Детальное представление кабеля среднего напряжения
Композитный вид кабеля среднего напряжения
Передовое производственное оборудование и технологии, строгая система контроля качества, высокая эффективность производства, отличные характеристики продукции, охрана окружающей среды.
нет данных
Электролитическая медь высокой чистоты
Выбор электролитической меди 1# с содержанием меди более 99,95%.
PVC/XLPE 
Хорошие электроизоляционные свойства, могут эффективно предотвратить утечку тока.
Стальная лента/Стальная проволока Бронированная
Устойчив к широкому спектру внешних воздействий и эрозии.
Медный щит
Хорошая проводимость и экранирующие свойства.
нет данных
Почему выбирают нас для проводов и кабелей?

№ 1, Jiangnan Cable обладает передовыми производственными технологиями и оборудованием. От производства проводников до обработки изоляции, экранирования и оболочки — каждый шаг является точным и строгим, чтобы обеспечить высокое качество кабелей среднего напряжения.


№ 2, контроль качества чрезвычайно строгий. Компания создала совершенную систему контроля качества, от выбора сырья до выхода готовой продукции с завода, проверяя на каждом уровне. Каждый кабель среднего напряжения должен пройти ряд строгих испытаний, чтобы гарантировать, что продукция соответствует национальным стандартам или даже превосходит их.


№3, компания Jiangnan Cable вложила значительные средства в исследования и разработки. В соответствии с рыночным спросом и особыми требованиями клиентов мы можем разработать кабели среднего напряжения с различными характеристиками, такими как лучшая устойчивость к воздействию окружающей среды и лучшая допустимая нагрузка по току. Более того, богатая линейка продуктов может удовлетворить различные потребности различных сложных проектов и предоставить клиентам универсальные кабельные решения.





Наши случаи

Что мы закончили

Мы имеем высокую степень глубины производства, короткое время выполнения и гибкость во всех смыслах. Что бы вы ни нуждались, мы рады помочь. Если у вас есть новая идея, которую вы хотите воплотить в жизнь, или существующий дизайн, который нуждается в улучшении, мы с нетерпением ждем возможности обсудить ее с вами.
нет данных


                                    Индивидуальное обслуживание Jiangnan Cable
Индивидуальные  Характеристики кабеля Изоляционный материал Строительство щита  Материал оболочки Структура брони Специальное исполнение Длина 
Сечение проводника Количество ядер Тип материала  Толщина изоляции  Тип экранирования Количество защитных слоев Выбор материала Цветовая идентификация  Тип брони Слои брони Огнестойкость Водонепроницаемость  Огнестойкие характеристики  Холодостойкость  Примеры счетчиков запросов на настройку

& Radic;

& Radic; & Radic; & Radic; & Radic; & Radic; & Radic; & Radic; & Radic; & Radic; & Radic; & Radic; & Radic; & Radic;

 

Заинтересованы?
Заказать звонок специалиста
Индивидуальные решения для ваших проектов по производству проводов и кабелей. Получите комплексные решения для индивидуальных проектов по производству проводов и кабелей. Получите техническую поддержку при проектировании, монтаже и корректировке проводных и кабельных конструкций.
Classification

Cable tunnels in a variety of forms and categories, different forms of tunnels with different operating characteristics, the importance of different.

Classification according to use

1. special tunnels: tunnels dedicated to the laying of power cables.

2. common ditch: also known as integrated pipe ditch, is a comprehensive corridor of underground urban pipelines, it is set up exclusively for a variety of public utilities to place a variety of pipeline tunnels under the ground

3.shared tunnels: refers to power cables and roads, railways and other municipal transport facilities used in common tunnels.

 Classified by voltage level

1.high-voltage tunnels: refers to cable tunnels in the cable voltage level are 110 kV and above.

2.low-voltage tunnels: cable tunnel cable voltage level are below 110 kV.

3.high and low voltage mixed tunnel: refers to cable tunnels within the cable voltage level is not strictly regulated.

Classification by access method

The access mode of cable tunnel refers to the form of power line access on both sides of the tunnel. Mainly includes three forms:

1. Both ends are substations.

2.one end of the substation, the other end of the overhead line access.

3. Both ends of the overhead line access.

Architectural features                           Characteristics of use

Due to the special use function, cable tunnels are generally long and narrow, with few entrances and exits, and the tunnels are fire blocked and have many obstacles.

1. Narrow space, few entrances and exits. Cable tunnels are a kind of closed and narrow structures, generally made of brick, stone and other non-combustible materials masonry, long and narrow space, usually about 1.8 m high, about 1.5 m wide, and some cable replacement of fewer places, there are also less than 1 m wide and high cable tunnels. In order to construction, maintenance, inspection of the convenience of the tunnel is generally left with a pedestrian access road, every few dozen metres to set up a maintenance entrance and ground connected.

2. Along the course of blocking, obstacles. There are several layers of cable supports on both sides of the tunnel, placing more cables. In the laying of cables, the tunnel is also set up inside the fire-resistant partition used to fire separation between the cable layers and blocking cable holes, to prevent the flame from penetrating and spreading of fire netting, firewalls set up in the relevant parts of the important circuit and fire-resistant compartments set up in the shaft and other fire separators, but these fire separators in the event of a fire, it will varying degrees of impediments to fire-fighting operations.

There are no other combustible materials in cable tunnels, and fires are generally caused by cables catching fire and burning. The insulating layers of cables are all combustible materials, and improper use and maintenance may cause fire.

Third, the characteristics of fire-fighting facilities

Cable tunnels are generally set up with mobile fire extinguishers and fixed fire extinguishing systems.

1. cable tunnels are configured according to the medium fire hazard level with a certain number of fire extinguishers, mainly ABC dry powder fire extinguishers.

2.cable tunnels set up a fixed fire extinguishing system usually carbon dioxide gas fire extinguishing system, gas fusion (smoke) fire extinguishing system and water spray fire extinguishing system.

3.Some larger cable tunnels are equipped with anti-smoke facilities.

Acceptance content

(1) lighting. Cable tunnels should be introduced from both ends of the low-voltage lighting power supply, and interval arrangement of lamps and lanterns, a two-way control switch. Lamps should be moisture-proof, explosion-proof type.

(2) Ventilation. Tunnel ventilation has natural ventilation and forced exhaust two ways. Urban roads on the cable tunnel, can be in the conditions of the green zone construction of inlet and outlet shaft, the use of inlet and outlet shaft height difference in the formation of air pressure, so that the natural circulation of air. Forced exhaust air needs to be installed fan, according to the tunnel volume and ventilation requirements for ventilation calculations, in order to determine the power of the fan and automatic on and off time.

(3) Drainage. The whole tunnel should have drainage channels, and there must be automatic drainage devices. If there is any infiltration water in the tunnel, it will be concentrated in the water collection pits at both ends, and when it reaches a certain water level, the automatic drainage device will be activated, and the water will be discharged to the city sewer by drainage pumps.

(4) Fire-fighting measures. In order to ensure the safety of cables, there must be reliable fire-fighting measures in the cable tunnel. Tunnel shall not be used with fibre-wrapped outer layer of the cable, should be used with fire-retardant properties, not externally combustible outer sheath of the cable, in the not positively combustible cable outer protective layer, should be coated with fire-resistant paint or wrapped around the fireproof wrapping tape. High-voltage cables should be covered with fireproof groove box made of durable fireproof material for the whole line. Such as single-core cables, can be zigzag arrangement, three-phase cover in a group of fire tank, fire tank ends with fire-resistant material plugging. Fire alarms and automatic fire extinguishing devices should also be installed in tunnels.

нет данных
Our related products
нет данных
Наши сопутствующие сертификаты 
нет данных
Мы являемся национальным ключевым предприятием высоких и новых технологий, специализирующимся на производстве, продаже и исследованиях проводов и кабелей.
Контактное лицо: Вилко Чжун
Контактный номер: 86-13372003527
Электронная почта: wilco@jncable.com.cn
WhatsApp: 86-13372003527
Контактное лицо : Келли Лу
Контактный номер: 86-17368475715
Электронная почта: kelly@jncable.com.cn
WhatsApp: 86-17368475715
Авторское право © 2024 Цзяннань Кабель  | Карта сайта
Customer service
detect