loading

Naqillərin və Kabellərin Tədqiqatına, İnkişafına, İstehsalına və Satışına Fokuslanmaq.

about railway cable
Railway Cable

Railway cable, that is, the application of special wires on the railway, railway power cable is used for the transmission and distribution of electrical energy cables, commonly used in urban underground power grids, power station lead lines, industrial and mining enterprises, internal power supply and over the river and sea underwater transmission lines.

məlumat yoxdur
Specification

Railway cable general specifications are: 1, plastic insulation and PVC outer sheath railway signal cable 2-48 cores, mostly used in automatic device system; 2, polyethylene insulation and comprehensive outer protective sheath of 4-61 cores, can transmit general automatic signals and frequency shifting automatic blocking and other audio signals.

Characteristics

1The ambient temperature of railway cable is -40~60;

2, railway cable allows long-term working environment temperature can not exceed 70 .

3, railway cable laying ambient temperature in the railway cable, PVC protective coat of the railway cable should not be lower than 0 , polyethylene protective coat of the cable should not be lower than -10 .

Orta Gərginlikli Kabel Təfərrüatları Şousu
Orta Gərginlikli Kabel Kompozit Görünüşü
Qabaqcıl istehsal avadanlığı və texnologiyası, ciddi keyfiyyətə nəzarət sistemi, yüksək istehsal səmərəliliyi, əla məhsul performansı, yaşıl ətraf mühitin qorunması
məlumat yoxdur
Yüksək saflıqda elektrolitik mis
Mis tərkibi 99,95%-dən çox olan 1# elektrolitik misin seçilməsi
PVC/XLPE 
Yaxşı elektrik izolyasiya xüsusiyyətləri, cərəyan sızmasının qarşısını effektiv şəkildə ala bilər
Polad lent/Polad məftil Zirehli
Xarici stresslərə və eroziyaya qarşı davamlıdır
Mis Qalxan
Yaxşı keçiricilik və qoruyucu xüsusiyyətlər
məlumat yoxdur
Niyə tel və kabel üçün bizi seçməlisiniz?

NO.1, Jiangnan Kabel qabaqcıl istehsal texnologiyası və avadanlıqlarına malikdir. Orta gərginlikli kabellərin yüksək keyfiyyətini təmin etmək üçün keçiricilərin istehsalından tutmuş izolyasiya, ekranlama və örtüklərin emalına qədər hər bir addım dəqiq və ciddidir.


NO.2, keyfiyyətə nəzarət son dərəcə ciddidir. Şirkət xammalın seçilməsindən tutmuş fabrikdən çıxan hazır məhsulların hər səviyyədə yoxlanılmasına qədər mükəmməl keyfiyyət yoxlama sistemi qurmuşdur. Hər bir orta gərginlikli kabel məhsulların milli standartlara cavab verməsini və ya hətta aşmasını təmin etmək üçün bir sıra ciddi sınaqlardan keçməlidir.


NO.3, Jiangnan Cable tədqiqat və inkişafa böyük sərmayə qoyub. Bazar tələbinə və müştərilərin xüsusi tələblərinə uyğun olaraq, daha yaxşı ətraf mühitə davamlılıq və daha yaxşı cərəyan keçirmə qabiliyyəti kimi müxtəlif xüsusiyyətlərə malik orta gərginlikli kabellər hazırlaya bilərik. Bundan əlavə, zəngin məhsul xətti müxtəlif kompleks layihələrin müxtəlif ehtiyaclarını ödəyə bilər və müştərilərə bir pəncərəli kabel həlləri təqdim edə bilər.





Əslar

Nə qurduq

Biz yüksək dərəcədə istehsal dərinliyinə, qısa müddətə və hər mənada çevikliyə sahibik. Ehtiyacınız nə olursa olsun, kömək etməkdən məmnunuq. Əgər reallaşdırmaq istədiyiniz yeni ideyanız və ya təkmilləşdirilməsi lazım olan mövcud dizaynınız varsa, onu sizinlə müzakirə etmək fürsətini gözləyirik.
məlumat yoxdur


                                    Jiangnan Kabel Xüsusi Xidməti
Xüsusi  Kabel Xüsusiyyətləri İzolyasiya materialı Qalxan tikintisi  Qapaq materialı Zireh quruluşu Xüsusi Performans Uzunlıqi 
Dirijor Kesiti Nüvələrin sayı Material növü  İzolyasiya Qalınlığı  Qoruyucu tip Qoruyucu qatların sayı Materiyi Seçimə Rəng İdentifikasiyası  Zireh növü Zireh qatları Yanğın müqaviməti Suya davamlı performans  Alov gecikdirici performans  Soyuq müqavimət  Nümunə fərdiləşdirmə tələbi sayğacları

 

Maraqlıdır?
Bir Mütəxəssisdən Zəng Edin
Tel və kabel layihələriniz üçün fərdi həllər. Fərdiləşdirilmiş məftil və kabel layihələri üçün tam həllər əldə edin. Tel və kabel konstruksiyalarının dizaynı, quraşdırılması və korreksiyası üçün texniki dəstək alın.

Types and applications

Railway cables can be divided into: communication cables, signal cables, traction power supply cables, etc. according to the use. Communication cables are mainly used for communication along the railway, signal cables are used for railway signalling system, and traction power supply cables are used for electric traction. With the development of the times, these cables are not only upgraded in their traditional functions, but also play an important role in emerging fields, such as the application of optical fibre cables in high-speed railway communications.

Railway Signal Cable

Suitable for rated voltage AC 500V or DC 1000V and below to transmit railway signals, audio signals or control circuits of automatic signaling devices, in which the integrated sheath, aluminium sheath railway signal cables have a certain degree of shielding performance, suitable for electrification sections or other areas with strong electrical interference laying.

Model name

PTYV Polyethylene Insulated PVC Sheathed Railway Signal Cable

PTYY Polyethylene insulated polyethylene sheathed railway signal cable

PTY22 Polyethylene Insulated Steel Tape Armoured PVC Sheathed Railway Signal Cable

PTY23 Polyethylene insulated steel tape armoured polyethylene sheathed railway signal cable

PTYA Polyethylene insulated composite sheathed railway signal cable

PTYA22 Polyethylene insulated composite sheathed steel tape armoured PVC sheathed railway signal cable

PTYA23 (PTYAH23) Polyethylene insulated composite sheathed steel tape armoured polyethylene outer sheath railway signal cable

PTYL22 Aluminium sheathed polyethylene insulated steel tape armoured PVC sheathed railway signal cable

PTYL23 (PTYLH23) Aluminium sheathed polyethylene insulated railway signal cable with steel belt armouring polyethylene outer sheath

Use characteristics

(1) The ambient temperature of the cable is -40~+60. 

(2) The long-term working temperature of cable conductor should not exceed +70. 

(3) Cable laying ambient temperature: PVC sheathed cable should not be less than 0 ; polyethylene sheathed cable should not be less than -20 .

(4) The permissible bending radius of the cable: non-armoured cable should be not less than 10 times the outer diameter of the cable; armoured cable should be not less than 15 times the outer diameter of the cable.

(5) Ideal shielding coefficient of railway signal cable with integrated sheath 0.8; Ideal shielding coefficient of railway signal cable with aluminium sheath 0.3

Delivery length of 500m and above should be not less than 50% of the total delivery length of the cable; 50 ~ 250m of the short section of the cable delivery length should be no more than 5% of the total delivery length; cable length measurement error should be no more than ± 0.5%. According to the length of delivery specified by mutual agreement

Specification

(4---61) cores X 1.0mm

Signal cable type identification

1. Signal cables include plastic sheath (PTY03, PTY23), comprehensive sheath (PTYA23, PTYA22), aluminium sheath (PTYL23, PTYL22) signal cables according to the type of sheath;

2. Signal digital cables are divided into plastic sheath (SPTYW03, SPTYW23), comprehensive sheath (SPTYWA23) aluminium sheath (SPTYWL23), internal shield (SPTYWP03 or SPTYWP23, SPTYWPA23, SPTYWPL23) digital signal cables.

SP-Digital Signal Cable

T-Railway

YW-Skin-foam-skin physical foamed polyethylene insulation

P-Inner Shield

L-Aluminium sheath

A-composite sheath

23-Double steel belt armoured polyethylene outer sheath

03-Polyethylene outer sheath

məlumat yoxdur
Our related products
məlumat yoxdur
Əlaqəli Sertifikatlarımız 
məlumat yoxdur
Biz naqillər və kabellər üzrə istehsal, satış və tədqiqat sahəsində ixtisaslaşmış Milli Key High və New Tech Enterpriseyik.
Əlaqədar şəxs: Wilco Zhong
Əlaqə nömrəsi: 86-13372003527
WhatsApp: 86-13372003527
Əlaqədar şəxs : Kelly Lu
Əlaqə nömrəsi: 86-17368475715
WhatsApp: 86-17368475715
Copyright © 2025 Jiangnan kabeli  | Sitt