Type | Name | Application |
YJV | Copper conductor XLPE insulated PVC sheathed Power cable | For laying indoors 、 in tunnels or cable trench ,unable to bear external mechanical forces. Single-core cable in magneticduct is not permissible. |
YJLV | Aluminum conductor XLPE insulated PVC sheathed Power cable | |
YJY | Copper conductor XLPE insulated PE sheathed Power cable | |
YJLY | Aluminum conductor XLPE insultated PE sheathed Power cable | |
YJV22 | Copper conductor XLPE insulated steel tape armored PVC sheathed Power cable | For laying in doors 、 in tunnels or cable trench,or direct in ground, able to bear external mechanical forces,but unable to bear large pulling force. |
YJLV22 | Aluminum conductor XLPE insulated steel tape armored PVC sheathed Power cable | |
YJV23 | Copper conductor XLPE insulated steel tape armored PE sheathed Power cable | |
YJLV23 | Aluminum conductor XLPE insulated steel tape armored PE sheathed Power cable | |
YJV32 | Copper conductor XLPE insulated steel wire armored PVC sheathed Power cable | For laying in doors 、 in tunnels, cable trench .well o r direct in ground , able to bear external mechanical forces and Determinate pulling force. |
YJLV32 | Aluminum conductor XLPE insulated steel wire armored PVC sheathed Power cable | |
YJV33 | Copper conductor XLPE insulated steel wire armored PE sheathed Power cable | |
YJLV33 | Aluminum conductor XLPE insulated steel wire armored PE sheathed Power cable |
Production Range of Cable: | ||||||
Type | No. of cores | Nominal Cross sectional area mm2 | ||||
Copper conductor | Aluminum conductor | |||||
YJV YJY YJV62 YJV63 | YJLV YJLY YJLV62 YJLV63 | 1* | 1.5-800 10-800 | |||
YJV YJY YJV22 YJV23 YJV32 YJV33 | YJLV YJLY YJLV22 YJLV23 YJLV32 YJLV33 | 2 | 1.5- 400 2.5- 400 10-400 | |||
YJV YJY YJV22 YJV23 YJV32 YJV33 | YJLV YJLY YJLV22 YJLV23 YJLV32 YJLV33 | 3 | 1.5- 630 2.5- 630 10-630 | |||
YJV YJY YJV22 YJV23 YJV32 YJV33 | YJLV YJLY YJLV22 YJLV23 YJLV32 YJLV33 | 4 | 1.5- 500 2.5- 500 10-500 | |||
YJV YJY YJV22 YJV23 YJV32 YJV33 | YJLV YJLY YJLV22 YJLV23 YJLV32 YJLV33 | 3+1 | 1.5-630 4-630 10-630 | |||
YJV YJY YJV22 YJV23 YJV32 YJV33 | YJLV YJLY YJLV22 YJLV23 YJLV32 YJLV33 | 5 | 1.5- 500 2.5- 500 10-500 | |||
YJV YJY YJV22 YJV23 YJV32 YJV33 | YJLV YJLY YJLV22 YJLV23 YJLV32 YJLV33 | 4+1 | 1.5-500 4-500 10-500 | |||
YJV YJY YJV22 YJV23 YJV32 YJV33 | YJLV YJLY YJLV22 YJLV23 YJLV32 YJLV33 | 3+2 | 1.5-500 4-500 10-500 | |||
* The armoured single-core cables are used for D. C. system only. As for A. C. system, non-magnetic armour material should be used, or magnetic isolation should be applied. |