loading

Focusing On The Research, Development, Production And Sales Of Wires And Cables.

Railway cable(旧)

about railway cable
Railway Cable

Railway cable, that is, the application of special wires on the railway, railway power cable is used for the transmission and distribution of electrical energy cables, commonly used in urban underground power grids, power station lead lines, industrial and mining enterprises, internal power supply and over the river and sea underwater transmission lines.

no data
Specification

Railway cable general specifications are: 1, plastic insulation and PVC outer sheath railway signal cable 2-48 cores, mostly used in automatic device system; 2, polyethylene insulation and comprehensive outer protective sheath of 4-61 cores, can transmit general automatic signals and frequency shifting automatic blocking and other audio signals.

Characteristics

1The ambient temperature of railway cable is -40~60;

2, railway cable allows long-term working environment temperature can not exceed 70 .

3, railway cable laying ambient temperature in the railway cable, PVC protective coat of the railway cable should not be lower than 0 , polyethylene protective coat of the cable should not be lower than -10 .

Types and applications

Railway cables can be divided into: communication cables, signal cables, traction power supply cables, etc. according to the use. Communication cables are mainly used for communication along the railway, signal cables are used for railway signalling system, and traction power supply cables are used for electric traction. With the development of the times, these cables are not only upgraded in their traditional functions, but also play an important role in emerging fields, such as the application of optical fibre cables in high-speed railway communications.

Railway Signal Cable

Suitable for rated voltage AC 500V or DC 1000V and below to transmit railway signals, audio signals or control circuits of automatic signaling devices, in which the integrated sheath, aluminium sheath railway signal cables have a certain degree of shielding performance, suitable for electrification sections or other areas with strong electrical interference laying.

Model name

PTYV Polyethylene Insulated PVC Sheathed Railway Signal Cable

PTYY Polyethylene insulated polyethylene sheathed railway signal cable

PTY22 Polyethylene Insulated Steel Tape Armoured PVC Sheathed Railway Signal Cable

PTY23 Polyethylene insulated steel tape armoured polyethylene sheathed railway signal cable

PTYA Polyethylene insulated composite sheathed railway signal cable

PTYA22 Polyethylene insulated composite sheathed steel tape armoured PVC sheathed railway signal cable

PTYA23 (PTYAH23) Polyethylene insulated composite sheathed steel tape armoured polyethylene outer sheath railway signal cable

PTYL22 Aluminium sheathed polyethylene insulated steel tape armoured PVC sheathed railway signal cable

PTYL23 (PTYLH23) Aluminium sheathed polyethylene insulated railway signal cable with steel belt armouring polyethylene outer sheath

Use characteristics

(1) The ambient temperature of the cable is -40~+60. 

(2) The long-term working temperature of cable conductor should not exceed +70. 

(3) Cable laying ambient temperature: PVC sheathed cable should not be less than 0 ; polyethylene sheathed cable should not be less than -20 .

(4) The permissible bending radius of the cable: non-armoured cable should be not less than 10 times the outer diameter of the cable; armoured cable should be not less than 15 times the outer diameter of the cable.

(5) Ideal shielding coefficient of railway signal cable with integrated sheath 0.8; Ideal shielding coefficient of railway signal cable with aluminium sheath 0.3

Delivery length of 500m and above should be not less than 50% of the total delivery length of the cable; 50 ~ 250m of the short section of the cable delivery length should be no more than 5% of the total delivery length; cable length measurement error should be no more than ± 0.5%. According to the length of delivery specified by mutual agreement

Specification

(4---61) cores X 1.0mm

Signal cable type identification

1. Signal cables include plastic sheath (PTY03, PTY23), comprehensive sheath (PTYA23, PTYA22), aluminium sheath (PTYL23, PTYL22) signal cables according to the type of sheath;

2. Signal digital cables are divided into plastic sheath (SPTYW03, SPTYW23), comprehensive sheath (SPTYWA23) aluminium sheath (SPTYWL23), internal shield (SPTYWP03 or SPTYWP23, SPTYWPA23, SPTYWPL23) digital signal cables.

SP-Digital Signal Cable

T-Railway

YW-Skin-foam-skin physical foamed polyethylene insulation

P-Inner Shield

L-Aluminium sheath

A-composite sheath

23-Double steel belt armoured polyethylene outer sheath

03-Polyethylene outer sheath

no data
Our related products
no data
Our Related Certifications 
no data
We are a National Key High and New Tech Enterprise specialized in production, sales and research on wires and cables.
Contact person: Wilco Zhong
Contact number: 86-13372003527
WhatsApp: 86-13372003527
Contact person: Kelly Lu
Contact number: 86-17368475715
WhatsApp: 86-17368475715
Copyright © 2025 Jiangnan Cable | Sitemap
Customer service
detect